Yasunaka's Measuring Instrument for Auricular Head Height


File Description SizeFormat
acta05_04_07_t.pdf354.57 kBAdobe PDFView/Open

Title: Yasunaka's Measuring Instrument for Auricular Head Height
Authors: Yasunaka, Masaya
Authors (alternative): 安中, 正哉
Issue Date: 25-Mar-1961
Citation: Acta medica Nagasakiensia. 1961, 5(4), p.182-187
Abstract: An instrument devised by the author for measurement of auricular head height and its use are reported. For the comparative evaluation of this method (the new method) with the modification of the direct method described by Martin (the old method), the author and two other measurers took measurement of the auricular head height in a series of 78 students with the old method and with the new method, and obtained the following results: 1) The difference between the maximum and minimum values determined on the individual subjects by three measurers independently averages 5.45mm.(σ=3.10) with the old method and 2.62 mm.(σ=1.78) with the new method. 2) The difference between the trained measurer and the two untrained measurers, respectively, averages 3.06 mm.(σ=2.48)and 4.32 mm.(σ=3.16) with the old method, and 1.59 mm.(σ=1.46)and 1.49 mm.(σ=1.31) with the new method.
URI: http://hdl.handle.net/10069/15447
ISSN: 00016055
Type: Departmental Bulletin Paper
Text Version: publisher
Appears in Collections:Volume 5, No. 4

Citable URI : http://hdl.handle.net/10069/15447

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace