Title: 近赤外線法による体脂肪計の測定条件に関する基礎的検討
Other Titles: Practical evaluation of the instrument for estimation of body composition by near infrared spectroscopy
Authors: 勝野, 久美子 / 福山, 由美子 / 西山, 久美子 / 浦田, 秀子 / 大塚, 健作
Authors (alternative): Katsuno, Kumiko / Fukuyama, Yumiko / Nishiyama, Kumiko / Urata, Hideko / Otsuka, Kensaku
Issue Date: 31-Mar-1992
Citation: 長崎大学医療技術短期大学部紀要 = Bulletin of the School of Allied Medical Sciences, Nagasaki University. 1992, 5, p.23-32
Abstract: 近赤外線法を利用した体脂肪計(FITNESS ANALYZER BFT2000)の測定条件について検討した.その結果,10回連続測定による再現性は,プローブ当て続け,毎回当て直しいずれも良好であった.皮膚面からプローブが浮いた状態および直射日光下の測定ではかなり高値となり,皮膚面を布で覆うと低値となった.また当てる位置がヨコ方向にずれると値が変動した.しかし,測定者間,他者と自己測定,利き腕と非利き腕,プローブの当てる強さ,向き,屋内での遮光帯の有無,皮膚面の濡れ,温度,上腕部の圧迫による影響はほとんどなかった.BFT2000間の機器間差はほとんどなかったが,BFT2000と新機種BFT3000では3000による測定値が若干低く出る傾向があった. / The test for manipulation of Fitness Analyzer BFT2000, an instrument for estimation of percent fat (%Fat) in human by near infrared spectroscopy. The instrument is portable in size, and is consisted of a probe (for radiation of infrared ray and reception of interactance spectra), a main system box (circuit, computer, key boad and display) and a band for shade. Near infrared interactance spectra are measured on the anterior biceps by using a probe with a band for shade, then the values of %Fat computed from the spectral data is indicated on the display. The reproducibility of the values by BFT2000 was assessed by CV obtained from 10 replicated measurements ; the results were satisfactory for practical applications. A space between the probe and the skin made the values for %Fat higher. The values were also affected when the position of the probe was shifted from a middle line of the biceps, and were lowered by covering with cloths on the skin surface to place a probe. The values obtained from BFT3000, a new model of Fitness Analyzer were slightly lower than those from BFT2000.
Keywords: 近赤外線 / 体脂肪計 / FITNESS ANALYZER / 測定条件
URI: http://hdl.handle.net/10069/18152
ISSN: 09160841
Type: Departmental Bulletin Paper
Text Version: publisher
Appears in Collections:Volume 5

Citable URI : http://hdl.handle.net/10069/18152

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace