DSpace university logo mark
詳細検索
Japanese | English 

NAOSITE : Nagasaki University's Academic Output SITE > 030 医学部 > 030 紀要 > Acta Medica Nagasakiensia > Volume 54, No. 1 >

Comparison of Exercise Echocardiography in Patients with 18mm ATS-AP Aortic Prosthesis


ファイル 記述 サイズフォーマット
acta_54_1_15.pdf199.17 kBAdobe PDF本文ファイル

タイトル: Comparison of Exercise Echocardiography in Patients with 18mm ATS-AP Aortic Prosthesis
著者: Odate, Tomohiro / Hashizume, Koji / Ariyoshi, Tsuneo / Taniguchi, Shinichiro / Hashimoto, Wataru / Matsukuma, Seiji / Hisatomi, Kazuki / Eishi, Kiyoyuki
発行日: 2009年 7月
引用: Acta medica Nagasakiensia, 54(1), pp.15-20 ; 2009
抄録: There have been various arguments concerning the patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) for small valves. The objective of this study was to evaluate the postoperative hemodynamics in patients. Methods: The subjects were 6 patients [6 females aged 64 (17~74) years, with a median body surface area (BSA) of 1.37 (1.29~1.51) m2] who underwent AVR at our facility using the 18-mm ATS-AP and tolerated exercise loading. We estimated pressure gradient(PG) ,ejection fraction(EF), left ventricular mass Index(LVMI)at pre-operation and post-operation. Exercise echocardiography on an ergometer was performed before and 29.0 ± 14.4 months after surgery. We estimated PG and effective orifice area(EOAI) at rest and at exercise. We compared echo data between pre-operation and post-operation, between at rest and at exercise. Results: The effective orifice area index(EOAI) at rest was 0.92(0.75~1.06) cm2/m2. There was a significant change in the LVMI between pre-operation and post-operation[158.5(104.0~222.2) g/m2 versus 102.4(92.3~146.4) g/m2; P < 0.05]. However, There was no significant change in the EOAI[0.92(0.75~1.06) cm2/m2 versus 0.84(0.78~0.91) cm2/m2; P > 0.05] and mean PG[11.0(6.6~16) mmHg versus 14.0(6.3~16) mmHg; P > 0.05], on maximal exercise. Conclusion: In patients whose BSA were 1.37(1.29~1.51) m2,the 18-mm ATS-AP was suggested to be a prosthetic valve that improves myocardial remodeling and provides stable hemodynamics even during exercise.
キーワード: Aortic valve replacement / PPM / Exercise echocardiography
URI: http://hdl.handle.net/10069/22061
ISSN: 00016058
関連リンク : http://joi.jlc.jst.go.jp/JST.JSTAGE/amn/54.15
資料タイプ: Departmental Bulletin Paper
原稿種類: publisher
出現コレクション:Volume 54, No. 1

引用URI : http://hdl.handle.net/10069/22061

このリポジトリに保管されている文献はすべて著作権により保護されています。
印刷やダウンロード等データの複製は、調査研究・教育または学習を目的とする場合に限定されます。

 

Valid XHTML 1.0! Copyright © 2006-2015 長崎大学附属図書館 - お問い合わせ Powerd by DSpace