DSpace university logo mark
Advanced Search
Japanese | English 

NAOSITE : Nagasaki University's Academic Output SITE > Faculty of Engineering > Bulletin > Reports of the Faculty of Engineering, Nagasaki University > No.2 >

変圧器の直流励磁を利用した自然転流型逆変換装置の進み角制御について


File Description SizeFormat
kogaku00_02_05.pdf3.82 MBAdobe PDFView/Open

Title: 変圧器の直流励磁を利用した自然転流型逆変換装置の進み角制御について
Other Titles: On the leading angle control of natural commutating invefter using DC excitation of inverter transformer
Authors: 山田, 英二 / 浦, 憲一郎 / 筒井, 宣雄
Authors (alternative): Yamada, Eiji / Ura, Kenichiro / Tsutsui, Nobuo
Issue Date: Dec-1971
Publisher: 長崎大学工学部
Citation: 長崎大学工学部研究報告, (2), pp.34-40; 1971
Abstract: Because natural commutating inverter builts up AC output voltage following to circuit condition and valve action of inverter, AC output voltage and leading angle of inverter vary widely with change of load and disturbance. In order to operate this inverter stably, AC output voltage and leading angle of inverter must be controlled at constant value even if load changes. Then several steps have been taken for these purposes. But these can be done by controlling of DC excitation of inverter transformer. Constant control of AC output voltage by this method has been reported, so we discuss the constant control of leading angle by adjusting DC excitation of inverter transformer in this paper. It is proved theoretically in chapter 2 that the leading angle is controlled by DC excitation of inverter transformer. And this fact is proved experimentally by 6KW inverter in chapter 4. In chapter 4 we expressed the leading angle control system of invetter with block diagram also, and obitained the transient response of the system to reference input, load resistance and capacitance changes. From these steady state and transient responses, it has been pointed out that: (1) controllable domain of leading angle is determined by construction of inverter circuit, (2) the response speed of leading angle is determined by the time constant of DC source circuit of inverter, and (3) construction of the control system discussed here is easier than others.
URI: http://hdl.handle.net/10069/23762
ISSN: 02860902
Type: Departmental Bulletin Paper
Text Version: publisher
Appears in Collections:No.2

Citable URI : http://hdl.handle.net/10069/23762

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace