DSpace university logo mark
Advanced Search
Japanese | English 

NAOSITE : Nagasaki University's Academic Output SITE > Institute of Tropical Medicine > Articles in academic journal >

A novel high-throughput method for molecular serotyping and serotype-specific quantification of Streptococcus pneumoniae using a nanofluidic real-time PCR system


File Description SizeFormat
JMM63_528.pdf245.07 kBAdobe PDFView/Open

Title: A novel high-throughput method for molecular serotyping and serotype-specific quantification of Streptococcus pneumoniae using a nanofluidic real-time PCR system
Authors: Dhoubhadel, Bhim Gopal / Yasunami, Michio / Yoshida, Lay-Myint / Thi, Hien Anh Nguyen / Thi, Thu Huong Vu / Thi, Thuy Ai Nguyen / Watanabe, Kiwao / Suzuki, Motoi / Morimoto, Konosuke / Dang, Duc Anh / Ariyoshi, Koya
Issue Date: Apr-2014
Publisher: Society for General Microbiology
Citation: Journal of Medical Microbiology, 63(Pt 4), pp.528-539; 2014
Abstract: Serotype-specific quantification data are essential for elucidating the complex epidemiology of Streptococcus pneumoniae and evaluating pneumococcal vaccine efficacy. Various PCR-based assays have been developed to circumvent the drawback of labour-intensive and time-consuming culture-based procedures for serotype determination and quantification of pneumococcus. Here, we applied a nanofluidic real-time PCR system to establish a novel assay. Twenty-nine primer pairs, 13 of which were newly designed, were selected for the assay to cover 50 serotypes including all currently available conjugate and polysaccharide vaccine serotypes. All primer pairs were evaluated for their sensitivity, specificity, efficiency, repeatability, accuracy and reproducibility on the Fluidigm Biomark HD System, a nanofluidic real-time PCR system, by drawing standard curves with a serial dilution of purified DNA. We applied the assay to 52 nasopharyngeal swab samples from patients with pneumonia confirmed by chest X-ray to validate its accuracy. Minimum detection levels of this novel assay using the nanofluidic real-time PCR system were comparable to the conventional PCR-based assays (between 30 and 300 copies per reaction). They were specific to their targets with good repeatability (SD of copy number of 0.1), accuracy (within ±0.1 fold difference in log10 copy number) and reproducibility (SD of copy number of 0.1). When artificially mixed DNA samples consisting of multiple serotypes in various ratios were tested, all the serotypes were detected proportionally, including a minor serotype of one in 1000 copies. In the nasopharyngeal samples, the PCR system detected all the culturepositive samples and 22 out of 23 serotypes identified by the conventional method were matched with PCR results. We conclude that this novel assay, which is able to differentially quantify 29 pneumococcus groups for 45 test samples in a single run, is applicable to the large-scale epidemiological study of pneumococcus. We believe that this assay will facilitate our understanding of the roles of serotype-specific bacterial loads and implications of multiple serotype detections in pneumococcal diseases.
URI: http://hdl.handle.net/10069/34687
ISSN: 00222615
DOI: 10.1099/jmm.0.071464-0
Rights: © 2014 SGM.
Type: Journal Article
Text Version: author
Appears in Collections:Articles in academic journal

Citable URI : http://hdl.handle.net/10069/34687

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace