Title: Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
Authors: Kakinuma, Ryutaro / Moriyama, Noriyuki / Muramatsu, Yukio / Gomi, Shiho / Suzuki, Masahiro / Nagasawa, Hirobumi / Kusumoto, Masahiko / Aso, Tomohiko / Muramatsu, Yoshihisa / Tsuchida, Takaaki / Tsuta, Koji / Maeshima, Akiko Miyagi / Tochigi, Naobumi / Watanabe, Shun-ichi / Sugihara, Naoki / Tsukagoshi, Shinsuke / Saito, Yasuo / Kazama, Masahiro / Ashizawa, Kazuto / Awai, Kazuo / Honda, Osamu / Ishikawa, Hiroyuki / Koizumi, Naoya / Komoto, Daisuke / Moriya, Hiroshi / Oda, Seitaro / Oshiro, Yasuji / Yanagawa, Masahiro / Tomiyama, Noriyuki / Asamura, Hisao
Issue Date: 9-Sep-2015
Publisher: Public Library of Science
Citation: PLOS ONE, 10(9), e0137165; 2015
Abstract: Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P <.0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P <.0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary ves sels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.
URI: http://hdl.handle.net/10069/36039
DOI: 10.1371/journal.pone.0137165
Rights: © 2015 Kakinuma et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Type: Journal Article
Text Version: publisher
Appears in Collections:Articles in academic journal

Citable URI : http://hdl.handle.net/10069/36039

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace