Potentiometric CO sensors using anion-conducting polymer electrolyte: Effects of the kinds of noble metal-loaded metal oxides as sensing-electrode materials on CO-sensing properties


File Description SizeFormat
SABC287_42.pdf892.59 kBAdobe PDFEmbargo until 2021-05-15

Title: Potentiometric CO sensors using anion-conducting polymer electrolyte: Effects of the kinds of noble metal-loaded metal oxides as sensing-electrode materials on CO-sensing properties
Authors: Hyodo, Takeo / Takamori, Mari / Goto, Toshiyuki / Ueda, Taro / Shimizu, Yasuhiro
Issue Date: 15-May-2019
Publisher: Elsevier B.V.
Citation: Sensors and Actuators, B: Chemical, 287, pp.42-52; 2019
Abstract: Potentiometric CO-sensing properties of electrochemical gas sensors using an anion-conducting polymer as an electrolyte and a metal oxide (MO; Bi2O3, CeO2, In2O3, SnO2, or V2O5) loaded with or without 2.0 wt% noble metal (N; Ag, Au, Ir, Ru, Rh, Pd, or Pt) as an electrode material (EC(N/MO) or (EC(MO) sensor; N/MO: N-loaded MO) were investigated in wet synthetic air (57%RH) at 30 °C. Among all the EC(MO) sensors, the EC(CeO2) sensor showed the largest CO response and excellent CO selectivity against H2 and the EC(Bi2O3) sensor showed relatively large CO and H2 responses (no CO selectivity against H2). Other EC(MO) sensors hardly showed both CO and H2 responses. However, the Au loading just onto In2O3 and SnO2 was effective in improving the magnitude of CO and H2 responses of the EC(In2O3) and EC(SnO2) sensors, respectively, which resulted in relatively poor CO selectivity against H2. On the other hand, the Pt loading only onto SnO2 extremely enhanced only the magnitude of CO response of the EC(SnO2) sensor, and thus the EC(Pt/SnO2) sensor showed the most excellent CO selectivity against H2, among all the sensors in this study. The heat treatment of N/MO powders in H2 at 250 °C reduced only the H2 response of the EC(Au/SnO2) sensor, leading to an improvement of the CO selectivity of only the EC(Au/SnO2) sensor against H2. On the other hand, the heat treatment drastically enhanced both CO and H2 responses of the EC(Pt/SnO2) sensor, resulting in a decrease in its CO selectivity against H2. The CO and H2 responses of other EC(N/SnO2) sensors before and after the heat treatment in H2 at 250 °C were also examined, and the effectiveness of the noble metal loading and the heat treatment on the CO-sensing properties was discussed in this study. In addition, gas-sensing mechanism was also proposed on the basis of chemical surface states of representative N/MO.
Keywords: Anion-conducting polymer / Carbon monoxide / Metal oxide / Noble metal / Potentiometric gas sensor
URI: http://hdl.handle.net/10069/38877
ISSN: 09254005
DOI: 10.1016/j.snb.2019.02.036
Rights: ©2019, Elsevier. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/