DSpace university logo mark
Advanced Search
Japanese | English 

NAOSITE : Nagasaki University's Academic Output SITE > Faculty of Engineering > Bulletin > Reports of the Faculty of Engineering, Nagasaki University > Volume 30, No. 54 >

チューブラー遠心送風機の入口偏流による騒音への影響


File Description SizeFormat
KJ00000136468.pdf552.36 kBAdobe PDFView/Open

Title: チューブラー遠心送風機の入口偏流による騒音への影響
Other Titles: Noise Generated by Inlet Distortion Flow of Tubular Centrifugal Fan
Authors: 児玉, 好雄 / 林, 秀千人 / 淵上, 真一郎 / 三村, 雄次郎 / 脇山, 卓哉
Authors (alternative): Kodama, Yoshio / Hayashi, Hidechito / Fuchigami, Shinichirou / Mimura, Yujirou / Wakiyama, Takuya
Issue Date: Jan-2000
Citation: 長崎大学工学部研究報告 Vol.30(54) p.9-15, 2000
Abstract: The discrete frequency noise generated from a tubular centrifugal fan was investigated in relation to the resonance with the inlet duct, the interaction with the stator and the inlet distortion flow experimentally. The following results an obtains. It was shown that the length of the inlet duct makes a great influence to the resonance of the discrete frequency noise. At the tubular fans, the wake flow from the rotor diffuses rapidly, then the interaction of it with the stators done not occur. By the way there is the large distortion flow inlet distortion flow and the rotor makes the discrete frequency noise, the interaction noise. That is, it was cleared that the discrete frequency noise is not cause by the interaction with the stators and rotor, but by the inlet distortion flow and rotor. And it was indicated the method to reduce the level of the inlet noise by using the honeycomb in the bellmouth. The noise level can be reduced about 9 dB.
URI: http://hdl.handle.net/10069/5092
ISSN: 02860902
Type: Departmental Bulletin Paper
Appears in Collections:Volume 30, No. 54

Citable URI : http://hdl.handle.net/10069/5092

All items in NAOSITE are protected by copyright, with all rights reserved.

 

Valid XHTML 1.0! Copyright © 2006-2015 Nagasaki University Library - Feedback Powerd by DSpace